CMSIS-DAP Hardware may provide LEDs that indicate the status of the CMSIS-DAP Debug Unit.
It is recommended to provide the following LEDs for status indication:
- Connect LED: is active when the DAP hardware is connected to a debugger.
- Running LED: is active when the debugger has put the target device into running state.
◆ LED_CONNECTED_OUT()
__STATIC_INLINE void LED_CONNECTED_OUT |
( |
uint32_t |
bit | ) |
|
Debug Unit: Set status of Connected LED.
- Parameters
-
bit | status of the Connect LED.
- 1: Connect LED ON: debugger is connected to CMSIS-DAP Debug Unit.
- 0: Connect LED OFF: debugger is not connected to CMSIS-DAP Debug Unit.
|
◆ LED_RUNNING_OUT()
__STATIC_INLINE void LED_RUNNING_OUT |
( |
uint32_t |
bit | ) |
|
Debug Unit: Set status Target Running LED.
- Parameters
-
bit | status of the Target Running LED.
- 1: Target Running LED ON: program execution in target started.
- 0: Target Running LED OFF: program execution in target stopped.
|